33kV On load power transformer

  • product details
  • FAQ
  • Download

Features of Products

SZ11 series 33KV class On-load voltage regulation is a voltage regulation method by which a transformer can change the voltage
by changing the tap gear when operating under load. Power electronic component switches have the advantages of frequent switching,
no spark and long service life, so they can be used as on-load tap-changer for distribution transformers.

 

Standard

GB1094.1-2013; GB1094.2-2013; GB1094.3-2013; GB1094.5-2008; GB/T 6451-2008; GB/T1094.10-2003; JB/T10088-2004
IEC60076; SANS 780 STANDARDS

Features of Products

1. Meet or exceeds ANSI. IEC. GB. SANS. Standards
2. Safe Handling, Installation and Operation.
3. Attractive, modern appearance
4. Reasonable Structure
5. Fully-sealed
6. Higher system reliability
7. High security and reliability in operation
8. High capacity of overload and efficiency
9. Robust construction having excellent short circuit and thermal withstand capabilities
10. EVERPOWER Transformers are more efficient by Reduced no-load losses and Reduced load losses

Transformer normal service conditions

1.The height above the sea level is below 1000m;
2.Ambient temperature;
3.Highest air temperature+40℃;
4.Highest daily average air temperature+30℃;
5.Highest annual average air temperature+20℃;
6.Lowest outdoor air temperature-25℃;

SZ11 series 33kV on-load regulation power transformer technical data
Rated
Capacity
(kVA)
Voltage Group
        (kV)
Vector
Group
Impedance voltage Loss(kW) No-load
current
Weight(kg) L*B*H(mm)
Outline dimension
Gauge vertical
horizontal
 (mm)
High
Voltage
Low
Voltage
No-load Load Machine
weight
Oil
weight
Gross
weight
800     Yd11 6.5 1.30  10.40  1.00  1350.0  700 2780 2790*1220*2150 820/820
1000     1.52  12.80  1.00  1575.0  775 3290 2830*1240*2250 820/820
1250     1.86  15.40  0.90  1810.0  880 3845 2870*1310*2370 820/820
1600     2.24  18.43  0.80  2190.0  960 4295 2900*1510*2420 820/820
2000     2.88  20.25  0.70  2460.0  1090 4890 2920*1750*2450 820/820
2500 38.5   3.40  21.73  0.60  3010.0  1205 5660 2980*1840*2530 1070/1070
3150 36 11 7 4.04  26.01  0.56  3785.0  1500 7600 3150*2220*2620 1070/1070
4000 35 10 4.84  30.69  0.56  4690.0  1790 8500 3270*2390*2670 1070/1070
5000 34.5 6 5.80  36.00  0.48  5570.0  2015 9790 3470*2580*2950 1070/1070
6300 33   7.5 7.04  38.70  0.48  7380.0  2460 12620 3700*2580*2950 1475/1475
8000     Ynd11 9.84  42.75  0.42  8870.0  2650 14100 3850*2680*3150 1475/1475
10000     11.60  50.58  0.42  10020.0  2930 16500 3920*3720*3230 1475/1475
12500     8 13.66  59.85  0.40  12880.0  3710 19780 4010*2950*3410 1475/1475
16000     16.46  74.02  0.40  16120.0  4280 23950 4120*3180*3570 1475/1475
20000     19.46  87.14  0.40  18580.0  5230 29600 4330*3560*3990 1475/1475

Note:It can supply voltage regulating range of ±3×2.5%or ±2×2.5%forhigh-voltage on-load regulation transformer

 

THREE-PHASE OIL IMMERSED AMORPHOUS
ALLOY DISTRIBUTION TRANSFORMER TECHNICAL DATA

Rated
Capacity
(kVA)
Voltage Combination
        (kV)
Vector group No-load
Loss(kV)
Load Loss
(KW)
No-load
current
%
Impedance voltage
%
High
Voltage
HV tap changer
(%)
LV(kV)          
30         0.33  0.60  1.70  4.0 
50       0.43  0.87  1.30 
63       0.50  1.04  1.20 
80       0.60  1.25  1.10 
100       0.75  1.50  1.00 
125         0.85  1.80  0.90 
160         0.10  2.20  0.70 
200 13.8       0.12  2.60  0.70 
250 13.2 ±5 0.4   0.14  3.05  0.40 
315 11 ±2*2.5 0.415 Dyn11 0.17  3.65  0.50 
400 10.5   0.433 Dyn5 0.20  4.30  0.50 
500 10       0.24  5.15  0.50 
630 6       0.32  6.20  0.30  4.5 
800 10       0.38  7.50  0.30 
1000 6       0.45  10.30  0.30 
1250         0.53  12.00  0.20 
1600         0.63  14.50  0.20 
2000         0.75  17.40  0.20  5.0 
2500         0.90  20.20  0.20 

Note:It can supply voltage regulating range of ±4×2.5% for high-voltage on-load regulation transformer