Features of Products
S11 Series 33kV Class Distribution transformer is one of the important equipments in power supply and distribution system of industrial and mining enterprises and civil buildings.
It reduces 33kV network voltage to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60) Hz, three-phase maximum rated capacity 2500kVA, and can be used indoors(outside)
Standard
GB1094.1-2013; GB1094.2-2013; GB1094.3-2013; GB1094.5-2008; GB/T 6451-2008; GB/T 1094.10-2003; JB/T10088-2004
IEC60076; SANS 780 STANDARDS Features of Products
1. Meet or exceeds ANSI. IEC. GB. SANS. Standards
2. Safe Handling, Installation and Operation.
3. Attractive, modern appearance
4. Reasonable Structure
5. Fully-sealed
6. Higher system reliability
7. High security and reliability in operation
8. High capacity of overload and efficiency
9. Robust construction having excellent short circuit and thermal withstand capabilities
10. EVERPOWER Transformers are more efficient by Reduced no-load losses and Reduced load losses
S11 series 33kV three phase distribution transformer | |||||||||||||
Rated Capacity (kVA) |
Voltage Group (kV) |
Vector Group |
Impedance voltage | Loss(kW) | No-load current |
Weight(kg) | L*B*H(mm) Outline dimension |
Gauge vertical horizontal (mm) |
|||||
High Voltage |
Low Voltage |
% | No-load | Load | % | Machine weight |
Oil weight |
Gross weight |
|||||
50 | 6.5 | 0.21 | 1.21 | 2.0 | 195 | 205 | 590 | 1000*950*1450 | 550/550 | ||||
100 | 0.29 | 2.02 | 1.8 | 320 | 240 | 790 | 1080*1000*1600 | 550/550 | |||||
125 | 0.34 | 2.38 | 1.7 | 395 | 270 | 950 | 1100*1030*1630 | 660/660 | |||||
160 | 0.36 | 2.83 | 1.6 | 460 | 285 | 1020 | 1130*1060*1630 | 660/660 | |||||
200 | 0.43 | 3.33 | 1.5 | 555 | 325 | 1170 | 1190*1060*1670 | 660/660 | |||||
250 | 38.5 | 0.51 | 3.96 | 1.4 | 630 | 340 | 1340 | 1260*1160*1700 | 660/660 | ||||
315 | 36 | 0.4 | Yyno | 0.61 | 4.77 | 1.4 | 720 | 400 | 1530 | 1280*1240*1790 | 660/660 | ||
400 | 35 | 0.415 | Dyn11 | 0.73 | 5.76 | 1.3 | 830 | 490 | 1780 | 1960*880*1900 | 820/820 | ||
500 | 34.5 | Dyn5 | 0.86 | 6.93 | 1.2 | 930 | 510 | 1960 | 2020*940*1920 | 820/820 | |||
630 | 33 | 0.433 | 1.04 | 8.28 | 1.1 | 1085 | 600 | 2290 | 2070*1010*2010 | 820/820 | |||
800 | 1.23 | 9.90 | 1.0 | 1270 | 660 | 2640 | 2240*1040*2150 | 820/820 | |||||
1000 | 1.44 | 12.15 | 1.0 | 1495 | 735 | 3100 | 2300*1200*2150 | 820/820 | |||||
1250 | 1.76 | 14.67 | 0.9 | 1775 | 830 | 3630 | 2450*1280*2250 | 1070/1070 | |||||
1600 | 2.12 | 17.55 | 0.8 | 2140 | 935 | 4235 | 2220*1510*2350 | 1070/1070 | |||||
2000 | 2.61 | 21.50 | 0.8 | 2535 | 1035 | 4910 | 2310*1740*2440 | 1070/1070 | |||||
2500 | 3.15 | 23.00 | 0.8 | 3140 | 1190 | 5840 | 2370*1840*2490 | 1070/1070 |
Note:It can supply voltage regulating range of ±5%or ±2×2.5% for high-voltage transformer