11kV /630A-20kA Vacuum Circuit Breaker

  • product details
  • FAQ
  • Download

Product Description

RVB type outdoor vacuum circuit breaker covering 12kV up to 36kV range for transformer substation and switch station using.
The current rating: 630A,....2500A, short circuit breaking current rating: 25kA,...40kA.
Its perfect design for instead of traditional type like OHB,VBF,3AF,ZW7,ZW30,ZW39,ZW37...etc.
More light, compact, reliable, and friend-enviromental.

Overview

Developed RVB-40.5 series of outdoor vacuum circuit breaker using modern processing technology and computer-aided design techniques,
combined with the latest generation of spring bodies and the advantages of a permanent institution. Its pursuit of high reliability,
easy to maintain design concepts to create a generation of superior product, is the most reliable electric power system the best option.
RVB-40.5series of switches of the main use software and solidwork designed with the overall nice, safe and reliable.
RVB-40.5Series switches have a variety of styles to choose from:
RVB-40.5Nordinary outdoor vacuum circuit breakers, spring actuator come standard with mechanical life of 20,000 times.
All series switches meet the following criteria:
ANSI/IEEE C37.60/IEC 62271-100( GB1984-2003 China standard)
GBT11022-1999 China Standard
IEC 60255-11
IEC 60255-21-1 Class I
IEC 60255-21-2 Class I
IEC 60255-21-3 Class I
IEC 60255-22-1 Class III
IEC 60255-22-2 Class IV
IEC 60255-22-3 Class III
IEC 60255-22-4 Class IV
RVB-40.5 Spring type VCB main characteristics
Reliable manual opening device
Reliable and labor-saving manual closing
Visible sub-closing indicator
IP64 protection class plug connector

Description:

Offering a unique design of the manual switch on technology to meet the state of conventional and unconventional features of the Closing. Its speed to meet IEC62271-100 and similar GB1984-2003 standard requirements.
The emergence of the technology to make up for the permanent institutions and agencies in their respective spring shortcomings, is a new generation of high-performance power switching distinguishing features.
Primary busbar terminal (direct overlap with the interrupter to reduce unnecessary power losses)
Vacuum interrupter (APG process using solid-solid insulating sealing technology, plus silicone rubber molding compound technology to improve the overall switch weather performance)
Extensible outlet pipe (plus modular design, which will help insulation margin of certainty and product interchangeability requirements)
RVB series vacuum switch rejection of the traditional switch design concepts, will absorb some of the advanced design concepts, simplifying the overall transmission mode switch,
greatly reducing the transmission power loss of this switch makes switching better overall performance and longer life.
Makes the whole body switches provide a higher life expectancy, more stable mechanical properties.
RVB-40.5N provide up to 25,000 times the mechanical operation of life, institutions 20,000 times the number of maintenance-free operation.
RVB-40.5Mto provide up to 100,000 times the mechanical operation of life

 

No. Item Unit Data
1 Rated voltage kV 12/24/36/40.5
2 Power frequency Wet 42/65/70/95  
Dry 45/70/80/110  
Lingthning impluse withstand voltage
(peak value)
75/95/125/150/170/185/200  
  Rated current A 630/1250/1600/2000/2500A
  Rated short circuit breaking current kA 25/31.5/40
  Rated capacitor bank breaking current A 600/800
  Rated short circuit breaking times times 30
  Rated making current kA 63/80/100
  Rated short circuit peak withstand current    
  Rated short circuit withstand current 25/31.5/40  
  Rated short time duration time s 3月4日
  Complete breaking time ms ≦100
  Opening time Highest
operate voltage
15-50  
  Rated
operate voltage
15-50  
  Lowest
operate voltage
30-60  
  Closing time 25-50 ≤3
  Contact closing bounce time ms ≤2
  Out of simultaneity of contact switching ms ≤2
  Contact overtravel on opening mm  
  Mectrical life 20000(Normal)  
  Electrical life(Rated onload switching) 10000(Noraml)  
  Rated operate sequence O-0.3-co-180s-co
  Weight ≤250kg

 

Specification
Rated capacity 12-36kV, 20-500VA
Input voltage 36000V
Output voltage 110/220V
Accuracy 0-2-3.0 and /or 3P or 6P
Usage Instrument
Phase Single
Coil structure Toroidal
Coil number Autotransformer
Certification IEC 60044-2,ANSI/IEEE C57.13

 

 

 

 

 


  • Previous:
  • Next: